southwestfireproofing

Type 5 MSDS
Home Previous Products Data Sheets Catalog Specifications UL Designs Application 2007 Directory Selection Chart Document Downloads Request or Contact



MATERIAL SAFETY DATA SHEET

                                            • Page 1 of 2

MSDS Number: CFP 911 Revision: 8

Date: January, 2005

SOUTHWEST FIREPROOFING PRODUCTS CO.

5119 Edith Boulevard, N. E.

Albuquerque, NM 87107

 

Telephone for Additional Information: (505) 345 -1633

SECTION I - PRODUCT IDENTIFICATION

Trade names and Synonyms: Cementitious Fireproofing, Type 5, Type 5GP, Type 5EF and Type 5MD.

Chemical Name and Family: Lightweight Gypsum Plaster

Chemical Formula: Blend of Gypsum, Vermiculite, Cellulose and minor amounts of other additives

CAS# (Chemical Abstract Service): Not Applicable (mixture)

TRANSPORTATION CLASSIFICATIONS

Surface Freight Classification: Wall Plaster

USA DOT CLASS: Non-hazardous

USA DOT ID#: Not Applicable

USA DOT LABEL: Not Applicable

CANADA Transportation of Dangerous Goods TDG CLASS: Non-hazardous

NPCA-HMIS HAZARD INDEX

Health: 1 Flammability: 0 Reactivity: 0 Personal Protection: B, E

SECTION II- HAZARDOUS INGREDIENTS/IDENTITY INFORMATION

Ingredient, Chemical & Common Name Percent by Weight CAS#

Gypsum (Calcium Sulphate Hemihydrate) Proprietary 7778-18-9

Vermiculite (Refined and Exfoliated) Proprietary 1318-00-9

Cellulose and additives Proprietary NA

Types 5, 5EF and 5MD also contain fiberglass reinforcement. All Type 5 Fireproofings are mixtures of dry materials that contain variable amounts of free silica and other minerals in dust form, which may become airborne during jobsite handling before adding water. Jobsite dust could assay more than 1% free silica which would require a reduction of the 15 mg/m3 total dust and the 5 mg/m3 respirable dust TLV per 29 CFR 1910.1000 Table 2 & 3.

SECTION III - PHYSICAL/CHEMICAL CHARACTERISTICS

Boiling Point: Not Applicable Specific Gravity: Not Applicable Vapor Pressure: Not Applicable Volatiles (%): Not Applicable Vapor Density: Not Applicable Evaporation Rate: Not Applicable Bulk Density (lb/ft3): 12 - 18 Solubility in Water: Slight pH Value (in water): 6 to 8

Odor Threshold: Unknown Appearance and Odor: Grey powder mixture that looks like insulation.

SECTION IV - FIRE AND EXPLOSION HAZARD DATA

Flash Point: None Flammable Limits: None

LEL: None UEL: None Extinguishing Media: None

Special Fire Fighting Procedures: None Unusual Fire and Explosion Hazards: None

SECTION V - REACTIVITY DATA

Stability: Stable under normal conditions.

Stability Conditions to Avoid: Product is stable. Although no hazardous reaction will occur, gypsum products should be kept dry until used to avoid hardening before use.

Incompatibility, Materials to Avoid: None known.

Hazardous Decomposition or Byproducts: Avoid direct exposure to excess heat of flame or electric arc welding and cutting. Remove fireproofing from metal substrate prior to such operations by scraping. Excessive heat may release Sulfur Dioxide as decomposition product.

Hazardous Polymerization: Will not occur.

Polymerization Conditions to Avoid: Not Applicable.

 

MSDS Number CFP 911, Rev 8 Page 2 of 2

 

 

 

SECTION VI - HEALTH HAZARD DATA

Toxicological Properties

Routes of Entry

Inhalation: Fireproofing dust released in handling or mixing may cause symptoms typical of nuisance dust including coughing, sneezing, and minor respiratory irritation. Long term inhalation of quartz or free silica containing dust may cause risk of silicosis, pneumoconiosis, dyspnea and decreased lung function.

Skin and Eye: Direct eye contact may cause minor physical or mechanical irritation. Prolonged or repeated skin contact may cause dry skin.

Ingestion: Not for consumption. If accidentally ingested, consult a physician immediately.

Carcinogenicity According to NTP, IARC, and OSHA: Not Applicable.

Medical Conditions Generally Aggravated by Exposure: None Known.

Emergency and First Aid Procedures: If inhaled, get fresh air. If symptoms persist, consult a physician. In case of eye contact, flush with eye wash or water. If irritation, blinking, or tearing persists, consult a physician. If ingested, see a physician.

SECTION VII - SPILL OR LEAK PROCEDURE

Steps to Be Taken in Case Material is Released or Spilled: Clean up spills with normal house cleaning methods and implements, but avoid creating excessive dust. The fireproofing is mixed with water for application and produces slippery conditions on floors and other surfaces. Keep wet mix scraped up and post signs to warn that the floors are slippery when wet.

Waste Disposal and Handling & Storage Special Precautions: Waste disposal must be in accordance with all applicable regulations for materials not defined as hazardous.

SECTION VIII - CONTROL MEASURES

Respiratory Protection: Wear dust mask, NIOSH, Type TC-84A, Protection N95 or equivalent for nuisance dust.

Ventilation: Local exhaust recommended to reduce dust levels.

Protective Gloves: Work gloves or hand creams may prevent drying of skin.

Eye Protection: Goggles are required for application of wet mix and where exposure to excessive dust is likely.

Other Protective Clothing: Normal work clothes.

Work/Hygienic Practices: Observe the precautions noted above.

Supplemental Information: Expanded vermiculite is one of the mix ingredients. Vermiculite ore bodies also contain other naturally occurring minerals in addition to vermiculite. These include tremolite and actinolite. Both of these minerals occur in two forms: Fibrous, which is asbestiform, and Massive, which is non-asbestiform.

The ore that we process has been tested by qualified environmental service and test groups to assure that there are "No Detectable Levels of Asbestos Present".

 

This material safety data sheet is furnished without charge to responsible persons who use it at their discretion and risk. Although the information and suggestions contained herein have been compiled, as of the issue date above, from sources believed to be reliable, there is no warranty of any kind, express or implied, as to the completeness or accuracy thereof.

 

©2004 Southwest Fireproofing Products Co.

Southwest Fireproofing, Type 5GP, Type 5EF, Type 5MD, Type 7GP, Type 7HD, Type 1XR, Type DK, Type HC and Type 7TB are trademarks of Southwest Fireproofing Products Company.